Analisis Penggunaan Energi Listrik Pada Pabrik VI PT. XYZ
DOI:
https://doi.org/10.25077/inomet.2.2.1-7.2024Keywords:
Konsumsi, Energi Listrik , Performance Rate , Specific Electric Energy Consumption (SEEC)Abstract
PT. XYZ, one of Indonesia's leading cement companies, has Factory VI as one of its production facilities. Factory VI has Raw Mill (6R1), Kiln (6W1), and Cement Mill (6Z1) machines. In its operational process, Factory VI requires a large amount of energy, especially electrical energy. Because the use of energy continues to increase from year to year, while the total cement production is constant, and the electricity tariff has not increased. Based on these problems, it is necessary to conduct a study entitled Analysis of Electrical Energy Use at the Factory VI of PT. XYZ.
Electricity is used to drive machines in cement production. Data processing shows that the pattern of electrical energy use is directly proportional to total cement production, with the magnitude of the influence of total cement production on electrical energy consumption being 88.67% on the 6R1 machine, 95.7% on the 6W1 machine and 86.57% on the 6Z1 machine. The use of electrical energy in 2021 on 6R1 is classified as wasteful; 6W1 is economical, and 6Z1 is economical. It was obtained that the average value of specific electric energy consumption (SEEC) and performance rate in 2021 on the 6R1 machine was 19.67 kwh/ton and 84.95%, the 6W1 machine was 30.17 kwh/ton and 88.59%, and the 6Z1 machine was 35.27 kwh/ton and 81.04%.
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Jurnal Inovasi Rekayasa Mekanikal dan Termal

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.